The electrical power meter, Xpert is a micro-controller based unit which measures various electrical parameters, and sequentially displays on a 128X64 backlit LCD.
The unit measures the three phase voltages, currents, frequency, power factors, individual Harmonic data as Histogram including Total Harmonic Distortion as well as individual current and voltage waveforms for all three phases. Based on these inputs, the system KVA, KW and KWh can also be calculated.
For the correct operation of the unit, the only basic care required is to ensure that the phase sequence of the three phases is R-Y-B and the polarity of the CT secondary is correct.
The unit is fully solid state and will give years of trouble-free service once installed correctly.
- Compact 96 X 96 X 55 mm!
- Graphical Display 128 X 64.
- Accuracy: Class 1.0 & Class 0.5 (Optional).
- Odd Harmonics up to 15th of individual Voltage and Current waveforms including THD.
- RS485 port for Communication EMS/ PLC/ SCADA (Optional).
- Dual Source Measurement (Optional).
- Two Relays - individually programmable for Alarm/ Trip (Optional).
- Histogram & Tabular display of Harmonic content.
- Wave shape display for all voltages & currents.
Parameters |
Type |
Name |
Statistics |
Input |
Supply |
Three Phases and Neutral of a 3P4W system / Three Phases
of a 3P3W system |
| Voltage |
Direct Voltage Input : 25 to 500V L-L, 20 to 300V L-N
PT Ratio : Site Selectable
Burden : 0.5VA |
| Current |
Secondary Current Input : 5A or 1A (Site Selectable)
CT Ratio : Site Selectable
Range of Reading : 5 – 5000A
Burden : < 1.0VA
Overload : 5A CT = 6A RMS Continuous
1A CT — 1.2A RMS Continuous |
| Power Supply |
Auxiliary Supply : 80 - 480 VAC, 50-60 Hz. |
|
Output |
Relay |
Two. Individually Field Programmable.
5A @ 250 VAC, Resistive Load |
|
MEASUREMENT |
True RMS Basic Parameters |
Voltage
(Volts L-N & L-L)
|
VL-N - Accuracy : 0.5% of Reading
VL-L - Accuracy : 1.0% of Reading |
Current
(Amps IR, IY, IB)
|
Accuracy : 0.25% of Reading |
| Line Frequency |
45 to 55 Hz, Accuracy : 0.3% of Reading |
| Power |
Active Power (P) |
Accuracy : 1% of Reading
(For IPFI>0.5) |
| Reactive Power (Q) |
Accuracy : 1.5% of Reading
(Between 0.5 Lag to 0.8 Lead)
|
| Apparent Power (S) |
Accuracy : 1% of Reading |
| Power Factor |
For Individual phases and System
Accuracy : 1.0% of Reading (IPFI=0.5)
Range of Reading : 0.05 to 1.00 Lag/Lead |
| Energy |
Total Active Energy (KWh) |
Range of Reading : 0 to 9999999.9
Accuracy : class 1.0S |
| Total Apparent Energy (KVAh) |
Range of Reading : 0 to 9999999.9
Accuracy : 1.0% of Reading |
| Total Apparent Energy (KVARh) |
Range of Reading : 0 to 9999999.9
Accuracy : 1.5% of Reading |
| Power Quality |
Individual Wave form for each voltage and
current |
| THD for each current and voltage in three
phases |
| MISC. |
Dimensions |
Bezel |
96 X 96 mm |
| Panel Cutout |
90 X 90 mm |
| Depth of installation |
55 mm |
| Display |
128X64 LCD |
| Operating temp |
10°C to 50°C |
| Weight |
0.35 Kgs (Approx.) |
| Min. Operating Current |
0.4% to 120% of CT primary |
| Comm |
RS485 |
Modbus-RTU protocol |
|