Home / Products / Three Phase Power Analyzer & Recorder / R2D2
R2D2 |
 |
Trinity has designed its Portable Power Analyzers, R2D2 to be the most versatile! Single Phase Power Analyzer and Recorder! available today. This next generation analyzer has important new features requested by our customers including LCD Display; USB Download & Motor mode for Three Phase balanced motor loads. From commercial & industrial, to residential monitoring, R2D2 has wide-ranging measurement and power quality analysis capabilities. These high performance capabilities, combined with the latest in electronic technology, make it ideal for both utility and industrial applications.
- A rugged full-featured instrument measuring all essential power quality data including Harmonics & Demands.
- Measures voltage, current, imbalance, power, energy, events, THD, individual harmonics, and frequency.
- Real-time, graphical display of harmonic content upto 15th.
- Integrated analysis and data retrieval capabilities of 8 MB in Oracle and 32 KB in R2D2 by USB port.
Accessories
1) Clamp-on CTs with Below Specification:
Ordering Information : Model, CT Ratio, Single / Triple Range, Colour
| Model S |
Transformer ratio
(Arms) |
600/300mA, 5A/2mA
(Single Range) |
| |
1A, 5A, 300mA
(Triple Range) |
| Overload (Arms) |
120% continuous, 200%
for 5 min/ h |
| Weight |
610 gm approx. |
| Colours |
Red, Yellow, Blue |
| Dimensions |
Overall 215(L) x 101(W)
x 40(D) mm. |
| 5000 Hz |
53 mm max. |
| Conductor size |
¯ 53 mm. |
| Bus bar |
51 x 12mm |
|
| Connections : |
Safety sockets for banana
plugs ¯ 4mm |
| Accuracy class |
2 |
1 |
0.5 |
| Rated burden |
0.8 W |
|
|
| Frequency range |
30Hz to
5000 Hz |
45 Hz to
1000Hz |
50 Hz to
400 Hz |
|
Note
Clamps with specifications other than above available subject to technical specifications.
Technical Specifications
| |
Parameter |
Statistics |
| Type |
Name |
|
ORACLE |
R2D2 |
True RMS
Basic Parameters |
Voltage
(Volts L-N) |
Direct Voltage Input |
0 to 300V AC |
| PT Ratio |
Freely Programmable up to 220KV |
Freely Programmable up to 66KV |
| Range of Reading |
0.0 to 220KV |
0.0 to 66KV |
| Accuracy |
0.5% of Reading |
Voltage
(Volts L-L) |
Direct Voltage Input |
0 to 51 0V AC |
| PT Ratio |
Freely Programmable up to 220KV |
Freely Programmable up to 66KV |
| Range of Reading |
0.0 to 220KV |
0. 0 to 66KV |
| Accuracy |
1.0% of Reading |
Current
(Amps Ir,
Iy, Ib) |
Secondary Current Input |
2mA, 300mA, 1000mA |
| CT Ratio |
Freely Programmable up to 9999A |
Freely Programmable up to 999A |
| Range of Reading |
0.0 to 9999A |
0.0 to 999A |
| Accuracy |
0.25% of Reading |
| Neutral Current |
Accuracy |
3% of Reading |
N/A |
| Line Frequency |
Range of Reading |
45 to 55 Hz |
| Accuracy |
0.3% of Reading |
| Power |
Active Power (P) |
Accuracy (Between 0.5 Lag to 0.8 Lead) |
1.0% of Reading |
| Reactive Power (Q) |
Accuracy (Between 0.5 Lag to 0.8 Lead) |
1.5% of Reading |
| Apparent Power (S) |
Accuracy |
1.0% of Reading |
| Power Factor |
Accuracy |
1% of Reading (IPFI>0.5) |
| Range of Reading |
0.05 to 1.00 Lag/Lead |
| Energy |
Total Active Energy (KWh) |
Range of Reading |
0 to 314780.00 MWh |
| Accuracy |
1.0S as per IS13779 |
Total Reactive Energy
(KVARh) |
Range of Reading |
0 to 314780.00 MWh |
Accuracy(Between 0.5 Lag to
0.8 Lead) |
1.5% of Reading |
Total Apparent Energy
KVAh) |
Range of Reading |
0 to 314780.00 MWh |
| Accuracy |
1.0% of Reading |
| Demand |
Active Power (KW) Demand |
Sliding & Fixed Selectable |
N/A |
| Apparent Power (KVA) Demand |
| Predictive Demand |
Fixed Window |
N/A |
| Power Quality |
Harmonics for Voltages |
3rd to 29th Odd Only |
3rd to 15th Odd Only |
| Harmonics for Currents |
3rd to 29th Odd Only |
3rd to 15th Odd Only |
| THD for each Voltage |
 |
 |
| THD for each Current |
 |
 |
| Misc. |
Phase angles |
 |
N/A |
| Run time |
 |
N/A |
Input Specifications
Supply
ORACLE : Three Phases and Neutral of a 3P4W system / Three phases of a 3P3W system.
R2D2 : One Phase and Neutral of a 1P2W system.
| |
ORACLE |
R2D2 |
| Voltage: |
|
| Direct Voltage Input |
Up to 510V L-L and 300V L-N |
| PT Ratio |
Freely Programmable up to 220KV Site selectable. |
Freely Programmable up to 66KV Site selectable. |
| Range of Reading |
1-220KV |
1-66KV |
| Burden |
0.5VA |
| Current: |
|
| Secondary Current Input |
5A or 1A |
| Range of Reading |
0 - 9999A |
0 - 999A |
| Burden |
< 1.0VA |
| Overload |
5A CT = 6A RMS Continuous 1A CT = 5A RMS Continuous |
Power Supply
Oracle : Self Power. Unit has in-built 3 phase supply with an operating range of 60 VAC - 480 VAC, 50-60 Hz. Mains supply (80-500 VAC) for connection at lab/office while downloadable data.
R2D2 : There are two entirely new sources of power. A small SMPS derives power from the line itself when connected to the electrical system, and powers the system. No need for adapter/battery.
During downloading process, since the unit connects to the PC/Laptop through USB cable, it derives power straight from USB port itself.
Data Logging
| Produrt |
Records |
Logging Interval |
Total Duration |
| Min. |
Max. |
| Oracle |
30395 |
1 Sec. 16.65 Min (999Sec.) |
8.4 Hours |
351.4 |
| R2D2 |
1025 |
02 Sec. to 16.65 Min (999Sec.) |
1 Hours |
12 Days |
| Display: |
320 X 240 Color TFT (In Oracle)
20 X 4 Line Graphics LCD (B/W), with LED backlight (In R2D2). |
| Dimensions: |
ORACLE : 225(W) X 198(H) X 80(D) mm.
R2D2: 110(W) X 220(H) X 45(D) mm. |
| Operating temp: |
10 °C to 50°C. |
Clamp-On CT Specification
| Transformer ratio (Arms): |
600A/300mA, 5A/2mA (Single Range); 1A, 5A, 300mA (Triple Range) |
For CTR 600A/300mA,
Weight : |
0.36 kg. |
| Dimension : |
overall 183(L) X 96(W) X 60 (D) mm |
| Conductor size : |
96 mm |
| Burden Resistance : |
≤ 2 ohms. |
| Accuracy : |
Class 0.5 |
| Frequency Range : |
50 to 400 Hz. |
|
|
|