Trinity
Home / Products / Load Manager / Maximum Demand Controller / Powerpro

Powerpro

Back

Electrical Power Meter

The Power Pro from Trinity is an easy-to-use, cost effective electrical power meter that offers all the basic measurement capabilities required to monitor an electrical installation. In addition to measuring the instantaneous parameters, it also measures accurately all three energies, and also demand, thus helping to measure and control energy costs.

Over the basic metering, it optionally provides two relay outputs, RS485 port supporting MODBUS RTU protocol, dual source metering and THD measurements.

Power pro
Power pro

The relays are site programmable for parameter of action, and the value on which to operate.

The CT primary and secondary, PT ratio and installation type are site selectable, thus making it possible to use the meter in all types of three phase installations.




  • Features
  • Specifications

Main Features:

  • Multiparameter Monitoring.
  • Measure All important Electrical Values
  • All parameters with default accuracy calss 1.0s.
  • Compact 96 X 96 X 55 mm DIN enclosure.
  • Optional RS-485 port for connection to SCADA/EMS.
  • Optional Alarm/Trip Output (Two) programmable for any parameter including Demand
Parameter
Type Name Statistics
Input Supply Three Phases and Neutral of a 3P4W system / Three Phases of a 3P3W system
Voltage Direct Voltage Input : Up to 500V L-L, Up to 300V L-N
PT Ratio: Site Selectable
Burden: 0.5VA
Current Secondary Current Input: 5A or 1A (Site Selectable)
CT Ratio: Site Selectable
Range of Reading   : 5 - 5000A
Burden: < 1.0V
Overload: 5A CT = 6A RMS Continuous
                1A CT = 1.2A RMS Continuous
Power
Supply
Auxiliary Supply: 90 - 480 VAC, 50-60 Hz.
Output Relay Two. Individually Field Programmable.
Switching Voltage: Max. 250 VAC
Switching Power : Max. 1000W
Expected Mechanical Life: >10 x 106 switching operations.
Expected Electrical Life : >4 x 106 switching operations.
@(Load = 200VA, Coscp = 0.5)
Measurment True RMS
Basic Parameters
Voltag
(Volts L-N
& L-L)
VL-N - Accuracy : 0.5% of Reading
VL-L - Accuracy  : 1.0% of Reading
Current
(Amps IR,
IY, IB)
Accuracy : 0.25% of Reading
Line
Frequency
45 to 55 Hz, Accuracy: 0.3% of Reading
Power Active
Power (P)
Accuracy: 1% of Reading
(For IPFI>0.5)
Reactive
Power (Q)
Accuracy: 1.5% of Reading
(Between 0.5 Lag to 0.8 Lead)
Apparent
Power (S)
Accuracy: 1%% of Reading
Powe
Factor
For Individual phases and System
Accuracy: 1.0% of Reading (IPFI20.5)
Range of Reading: 0.05 to 1.00 Lag/Lead
Energy Total
Active
Energy
(KWh)
Range of Reading: 0 to 9999999.9 KWh
Accuracy: 1.0s as per IS13779
Total
Apparent
Energ
(KVAh)
Range of Reading: 0 to 9999999.9 KWh
Accuracy: 1.0% of Reading
Total
Apparent
Energy
(KVARh)
Range of Reading: 0 to 9999999.9 KWh
Accuracy: 1.5% of Reading
Power
Quality
THD for each Voltage (Optional)
THD for each Current (Optional)
Demand KVA/ KW
Demand
Site Selectable. Demand Interval 15/30 Min. Also site selectable
Max.
Demand
Max. Value reached only. No time & date stamp
Dimensions Bezel 96 X 96 mm
Miscellaneous Panel
Cutout
92 X 92 mm
Depth of
installation
55 mm
  Display 16 X 1 Backlight LCD or 128 X 64 Graphical Backlight LCD(To be specified at the time of Ordering)
  Operatin
temp
10°C to 50°C
  Weight 0.35 Kgs (Approx.)
  Min.
Operating
Current
0.4% to 120% of CT primary
Comm. RS485 Modbus-RTU protocol

Back to top
Home | About us | Products | Career with us | Partner with us | News | Contacts | Clientele | Disclaimer | Sitemap
Copyright © 2005 - 2008 Trinity Energy Systems Pvt. Ltd., Powered by: Megh Technologies