Oracle

Trinity has designed its Portable Power Analyzers, ORACLE to be the most versatile instrument available today. Oracle which is, Three Phase Power Analyzer and Recorder, is our next generation analyzer, including important new features requested by our customers. From substations, to commercial & industrial, to residential monitoring, Oracle has comprehensive measurement and power quality analysis capabilities. These high performance capabilities, combined with the latest in electronic technology, make it ideal for both utility and industrial applications.

Back


Oracle

  • A rugged full-featured instrument measuring all essential power quality data including Harmonics & Demands.
  • Measures voltage, current, imbalance, power, energy, events, THD, individual harmonics, and frequency.
  • Real-time, graphical display of harmonic content upto 29th.
  • Integrated analysis and data retrieval capabilities of 8 MB by USB port.
 


  • Features
  • Specifications

Main Features:

  • Micro-controller based
  • All parameters with default accuracy class 1.0S
  • Easy user interface through Touch Screen with graphical color TFT display of 320x240 pixels

  • Comprehensive and Measurements


  • Fast, real-time cycle by cycle measurement, at 80 samples/cycle
  • Run Time trending and Historical Trends on local display
  • Four quadrant readings (Power and Power Factor)
  • Min. /Max. Values for all various parameters
  • KVA and KW Demands (sliding and fixed) including predictive demand with fixed window
  • Odd Harmonics up to 29th of individual Voltage, and Current Waveforms including THD
  • Waveform capture-upto 20 waveforms can be captured in the non-volatile memory, and later downloaded.
  • Measurement of all three voltages - phase to phase and phase to neutral, all three currents, power factors - phase wise and system, Hz, all three powers (KW, KVA & KVAR), phase wise and system, all three energies, Phase angles, Demand and Maximum Demand in KW and KVA with programmable integration period, neutral current, THD for each voltage and current.

  • Installations & Connections:


  • Single model accepts 3P4W and 3P3W connections
  • Selectable CT-Secondary to 2mA, 300 mA and 1000 mA
  • User selectable CT and PT Ratio

  • Communication:


  • Data logging interval of 1 sec is possible by using a single 32 bit micro-controller.
  • Logs all Min. /Max. Values
  • Logs all electrical parameters, real-time and integrated (energies and demands) and harmonics to get complete Energy system snap-shot

  • Events Logging:


  • Programmable four events to be logged for selectable parameters to High or Low
  • Date and Time for event loggings with Minimum and Maximum values

Technical Specifications

  Parameter Statistics
Type Name   ORACLE R2D2
True RMS
Basic Parameters
Voltage
(Volts L-N)
Direct Voltage Input 0 to 300V AC
PT Ratio Freely Programmable up to 220KV Freely Programmable up to 66KV
Range of Reading 0.0 to 220KV 0.0 to 66KV
Accuracy 0.5% of Reading
Voltage
(Volts L-L)
Direct Voltage Input 0 to 51 0V AC
PT Ratio Freely Programmable up to 220KV Freely Programmable up to 66KV
Range of Reading 0.0 to 220KV 0. 0 to 66KV
Accuracy 1.0% of Reading
Current
(Amps Ir, Iy, Ib)
Secondary Current Input 1A or 5A
CT Ratio Freely Programmable up to 9999A Freely Programmable up to 999A
Range of Reading 0.0 to 9999A 0.0 to 999A
Accuracy 0.25% of Reading
Neutral Current Accuracy 3% of Reading N/A
Line Frequency Range of Reading 45 to 55 Hz
Accuracy 0.3% of Reading
Power Active Power (P) Accuracy (Between 0.5 Lag to 0.8 Lead) 1.0% of Reading
Reactive Power (Q) Accuracy (Between 0.5 Lag to 0.8 Lead) 1.5% of Reading
Apparent Power (S) Accuracy 1.0% of Reading
Power Factor Accuracy 1% of Reading (IPFI>0.5)
Range of Reading 0.05 to 1.00 Lag/Lead
Energy Total Active Energy (KWh) Range of Reading 0 to 314780.00 MWh
Accuracy 1.0S as per IS13779
Total Reactive Energy
(KVARh)
Range of Reading 0 to 314780.00 MWh
Accuracy(Between 0.5 Lag to
0.8 Lead)
1.5% of Reading
Total Apparent Energy
KVAh)
Range of Reading 0 to 314780.00 MWh
Accuracy 1.0% of Reading
Demand Active Power (KW) Demand Sliding & Fixed Selectable N/A
Apparent Power (KVA) Demand
Predictive Demand Fixed Window N/A
Power Quality Harmonics for Voltages 3rd to 29th Odd Only 3rd to 15th Odd Only
Harmonics for Currents 3rd to 29th Odd Only 3rd to 15th Odd Only
THD for each Voltage
THD for each Current
Misc. Phase angles N/A
Run time N/A

Input Specifications

Supply

ORACLE : Three Phases and Neutral of a 3P4W system / Three phases of a 3P3W system.

R2D2 : One Phase and Neutral of a 1P2W system.

  ORACLE R2D2
Voltage:  
Direct Voltage Input Up to 510V L-L and 300V L-N
PT Ratio Freely Programmable up to 220KV Site selectable. Freely Programmable up to 66KV Site selectable.
Range of Reading 1-220KV 1-66KV
Burden 0.5VA
Current:  
Secondary Current Input 5A or 1A
Range of Reading 0 - 9999A 0 - 999A
Burden < 1.0VA
Overload 5A CT = 6A RMS Continuous 1A CT = 5A RMS Continuous

Power Supply

Oracle : Not needed when connected to bus. Unit has in-built 3 phase supply with an operating range of 60VAC 480 VAC, 50-60 Hz. Mains supply (80-500 VAC) for connection at lab/office while downloadedable data.

R2D2 : 12VDC Battery back which can last up to 80 Hours. Also 12VDC adapter connection is available which overrides battery.


Data Logging

Produrt Records Logging Interval Total Duration
Min. Max.
Oracle 9800 06 Sec. 16.65 Min (999Sec.) 16.33 Hours 113 Days
R2D2 1025 02 Sec. to 16.65 Min (999Sec.) 1 Hours 12 Days

Display: 320 X 240 Color TFT (In Oracle)
20 X 4 Line Graphics LCD (B/W), with LED backlight (In R2D2).
Dimensions: ORACLE : 225(W) X 198(H) X 80(D) mm.
R2D2: 110(W) X 220(H) X 45(D) mm.
Operating temp: 10 °C to 50°C.

Clamp-On CT Specification

Transformer ratio (Arms): 200/5A, 500/5A, 1000/5A (Single Range); 100, 500, 1000/5A (Triple Range)
Overload (Arms): 120% continuous, 200% for 5 min/ h
Colours: Red, Yellow, Blue
Jaw opening: 53 mm max.
Bus bar: 51 x 12mm
Accuracy: class 2
Frequency range: 30Hz to 5000 Hz
Weight: 610 gm approx.
Dimensions: Overall 215(L) x 101(W) x 40(D) mm.
Conductor size: Ø53 mm.
Connections: Safety sockets for banana plugs Ø4mm Rated burden 0.8 W